---
title: "AERL — Cathodic Protection Capability Statement"
revision: "1.0.0"
publisher: AERL (Australian Energy Research Laboratories)
url: https://www.aerl.com.au/docs/aerl-cp-capability-statement
pdf: https://www.aerl.com.au/documents/guides/AERL_Cathodic_Protection_Capability_Statement_REV_100.pdf
description: "AERL cathodic protection at a glance: ICCP power electronics and system components for remote pipelines, tanks and structures — converters, surge protection, solar charging, storage and monitoring — with applications and where they work."
---

# AERL — Cathodic Protection Capability Statement

*Rev 1.0.0. Markdown copy of the AERL document at https://www.aerl.com.au/docs/aerl-cp-capability-statement; the PDF (https://www.aerl.com.au/documents/guides/AERL_Cathodic_Protection_Capability_Statement_REV_100.pdf) is the controlled version.*

# Cathodic Protection. Power Electronics.

**1980s** Designing ICCP converters since the late 1980s

**98%** Peak converter efficiency, no fans

**1supplier** Converter, solar, storage and monitoring

**Global** Supplied to projects on three continents

Converters, solar power, storage, surge protection and monitoring for remote pipelines, tanks and structures.

## Cathodic Protection at AERL

ICCP since the late 1980s

AERL designs and supports solar‑powered impressed current cathodic protection (ICCP) for buried and submerged steel at remote sites: oil, gas and water pipelines, tanks and structures.

In the late 1980s AERL built a dedicated cathodic protection controller for off‑grid pipeline systems. Its ICCP Cathodic Converters™ earned a worldwide reputation for efficiency and reliability. Today AERL engineers the power electronics at the heart of a CP site, the CoolPro converter and its surge protection, and supplies every component around them: solar charge controllers, battery storage and remote monitoring, from one Australian team.

### Core Capabilities

01

#### CP power electronics

High‑current DC‑DC conversion with integrated ICCP control, designed in‑house.

02

#### Solar power for CP sites

CoolMax SRX MPPT charge controllers and LiFe² battery storage to run CP with no grid.

03

#### Remote monitoring

Converter readings on RS485 / Modbus RTU, through the Nexus Gateway to AERL Cloud or SCADA.

04

#### Lightning protection

Surge Buster module, 50 kA (8/20 µs), for long or tall structures. Made in Australia.

05

#### Survey‑ready control

1–2 ms current interruption for instant‑off surveys; reference‑cell potential control.

06

#### Design and support

System sizing, set‑up advice and Australian technical support for the life of the site.

### A Solar ICCP Site, Supplied by AERL

### Why AERL for Cathodic Protection

- ICCP converters designed by AERL since the late 1980s
- One supplier for the converter, solar, battery and monitoring
- Fan‑less, IP65 design for heat, dust and unattended sites
- Surge protection sized for long pipelines and tall structures

## The CP Range

From the solar array to the structure

| Function | AERL product | Role in a CP system |
|---|---|---|
| ICCP conversion | CoolPro Cathodic Converter™ | Turns battery power into a controlled protection current: constant current, voltage or structure potential. Up to 98% efficient, fan‑less, IP65; 30 A per unit, in parallel for more. |
| Surge protection | Surge Buster | 50 kA (8/20 µs) lightning protection on the converter’s input, output, interrupt and reference‑cell lines. Made in Australia. |
| Solar charging | CoolMax SRX · SRX‑R | MPPT charge controllers with up to 600 V PV input and up to 200% PV oversizing, wall‑mount or 2U rack. |
| Energy storage | LiFe² | 48 V LiFePO4 modules of 5.12 kWh, in parallel, to keep protection current flowing through the night and cloudy days. |
| Monitoring | CoolPro Meter Board · Nexus Gateway · AERL Cloud | Output current, voltage and structure potential over RS485 / Modbus RTU, sent over 4G or Ethernet with alerts. |
| DC insulation monitoring | EarthGuard EG‑600 | Detects insulation faults on two PV or battery circuits, 40–600 Vdc, with audible and visual alarms. |

### Engineered for CP Work

- Structure‑potential control (±2400 mV) for coated structures
- 1–2 ms current interruption for instant‑off surveys
- Output current held within ±0.5% over load and temperature
- Converters in parallel to protect the largest structures

### Applications

**Oil and gas pipelines**Remote transmission and gathering lines, where AERL’s CP story began.

**Water pipelines**Buried steel water mains far from grid power.

**Tanks and vessels**Structures where over‑protection harms coatings, using potential control.

### Where It Works

CoolPro converters supplied to pipeline and corrosion projects in:

- Australia
- United States
- Nigeria
- Egypt

### Trusted By

Among the pipeline and energy operators that rely on AERL equipment:

![Santos](https://www.aerl.com.au/docs/_assets/assets/images/clients/santos.svg) ![APA](https://www.aerl.com.au/docs/_assets/assets/images/clients/apa.svg) ![Epic Energy](https://www.aerl.com.au/docs/_assets/assets/images/clients/epic-energy.svg)

![AERL](https://www.aerl.com.au/docs/_assets/assets/logos/aerl-logo.svg)

Let’s talk about your CP project.

### Company

**Australian Energy Research Laboratories** Founded 1985 Trading entity: AERL Pty Ltd ABN 87 653 916 477

### Head office

1/75 Bluestone Circuit Seventeen Mile Rocks QLD 4073 Australia

### Contact

**1800 950 865** Sales: [sales@aerl.com.au](mailto:sales@aerl.com.au) Support: [support@aerl.com.au](mailto:support@aerl.com.au)

### CP range

**CoolPro** ICCP converters **Surge Buster** lightning protection CoolPro Meter Board

### Power and monitoring

CoolMax SRX charge controllers LiFe² battery storage Nexus Gateway · AERL Cloud

### Documents

CoolPro datasheet and manual Modbus RTU protocol Surge Buster datasheet

aerl.com.au **CP Capability Statement** Rev 1.0.0 · November 2026

© 2026 AERL Pty Ltd Information correct at November 2026 and subject to change. Customer names identify AERL customers only; all trademarks are the property of their owners.
