AERL technical documentation

Claiming STCs on Systems with Solar Charge Controllers · Installer Information Sheet Rev 1.0.0

3 pages

Download PDF Print
AERL · Claiming STCs with Solar Charge Controllers
Rev 1.0.020 Nov 2026
Download PDF· Rev 1.0.0
Installer Information Sheet

Claiming STCs on Systems with Solar Charge Controllers

Using the Generic Regulator Entry (NI0001) in the REC Registry
AERL CoolMax SRX · CoolMax SRX-R · Other DC-Coupled Solar Regulators

This information sheet explains how to claim small-scale technology certificates (STCs) for a solar PV system whose panels charge the battery through a solar charge controller (solar regulator), such as the AERL CoolMax SRX. Solar charge controllers are not listed on the Clean Energy Council (CEC) approved inverters list, and they do not need to be. The REC Registry has a generic entry for them.

Revision1.0.0
Effective11 / 2026
AudienceDesigners, installers and STC agents
SchemeSmall-scale Renewable Energy Scheme (SRES)

In Short

REC Registry fieldEnter
Inverter manufacturerRegulator
Inverter seriesRegulator
Inverter model numberNI0001

The entry is on the CER's CEC approved inverters list applicable from 11 November 2026, listed until 31 December 2030.

AERL · Claiming STCs with Solar Charge Controllers · Rev 1.0.0Page 1 / 3© 2026 AERL Pty Ltd
AERL · Claiming STCs with Solar Charge Controllers
Rev 1.0.020 Nov 2026

Which Entry to Use

SystemInverter field in the STC claim
DC-coupled, no inverter (DC loads only, such as telecommunications, pumping, monitoring and SCADA sites)Regulator / Regulator / NI0001
DC-coupled with a CEC-listed battery or multiple mode inverter (for example, an off-grid system with a Selectronic SP PRO)The listed inverter, as on the CEC approved inverters list. Do not enter the charge controllers.
AC and DC coupled together (a CEC-listed PV inverter on part of the array, charge controllers on the rest)The listed inverter(s). Do not enter the charge controllers.
DC-coupled with a battery inverter that is not on the CEC approved inverters listNot eligible. Every inverter in the system must be on the CEC approved inverters list; NI0001 is only for systems with no inverter.

In every case the system's rated power output is the total rated power of the panels (kW, up to three decimal places), not the rating of the charge controllers or the inverter. Count every eligible panel, including those connected through charge controllers.

What Is Still Required

The generic entry replaces the charge controller's listing only. Every other STC requirement still applies:

AERL · Claiming STCs with Solar Charge Controllers · Rev 1.0.0Page 2 / 3© 2026 AERL Pty Ltd
AERL · Claiming STCs with Solar Charge Controllers
Rev 1.0.020 Nov 2026

Charge Controller Compliance

Removing charge controllers from the STC inverter list does not remove their safety obligations. A charge controller connected to a PV array is power conversion equipment and must suit the array and battery it is installed with, under AS/NZS 5033 and the manufacturer's instructions.

The CoolMax SRX 600/55-48 and SRX 600/70-48 are certified to IEC 62109-1:2010 (Certificate of Suitability AZ 69026804). The CoolMax SRX-R 600/60-48 is CEC listed as other power conversion equipment until 8 April 2028; AERL will not renew the listing when it expires. That category is not on the STC inverter list, so the SRX-R listing is not entered in an STC claim, and claims are not affected when it lapses.

Keep the charge controllers' model and serial numbers, and photos of their nameplates and installation, with the job records. Your STC agent may ask for them.

Before You Claim

  1. Check every panel model against the current CEC approved PV modules list.
  2. Decide the inverter-field entry from Which Entry to Use.
  3. Ask your STC agent how they want the inverter serial number field and photos completed for an NI0001 claim. Their forms and systems set the evidence they collect.
  4. Record the total panel rating as the rated power output.
  5. Select the correct type of connection and complete the written statements.
Note

The CER sets the STC rules and the CEC approved lists change. This sheet reflects the CER guidance and lists published at 20 November 2026. Check the current requirements at cer.gov.au before you claim; the CER's decision on any claim is final. AERL is not an STC agent and cannot assess or create STC claims.

About This Sheet

RevisionDateChange
1.0.011 / 2026First issue.