AERL technical documentation

AERL Field Troubleshooting Guide Rev 1.0.0

30 pages

Download PDF Print
Download PDF· Rev 1.0.0 Troubleshooting Guide

Field Troubleshooting

Symptoms, Causes and Fixes Across the AERL Range

AERL Product Range Troubleshooting GuideRev 1.0.0, 8 Nov 2026
aerl.com.au © 2026 AERL Pty Ltd

Contents

AERL Field Troubleshooting GuideRev 1.0.0
AERL Field Troubleshooting GuideRev 1.0.0

Foreword

Document

Revision1.0.0
Effective11 / 2026
AudienceQualified installers and service technicians
Full referenceEach product's user manual
FormatA4 · 30 pages

This guide helps installers find and fix the faults most often met in the field on AERL products. It is organised by product, then by symptom. Each table gives what you see, its likely cause, what to check and the fix.

The guide summarises. Each product's user manual is the full reference: where a table names a chapter, it is the chapter of that product's manual. Use the latest manuals and software from aerl.com.au and aerl.com.au/professionals.

Danger — isolate before you work

Only qualified people may test, open or rewire this equipment. Battery and PV circuits stay live when an inverter or controller is switched off, and a DC arc does not self-extinguish. Follow your isolation procedure, prove dead with a meter rated for the system voltage, and wear PPE.

Before You Start

AERL Field Troubleshooting GuideRev 1.0.0
01

CoolMax SRX and SRX-RStatus LED, not starting or sleeping

The full list of warning and fault codes is in Chapter 13, Troubleshooting, of the CoolMax SRX and SRX-R user manuals. AERL Link (aerl.com.au/professionals) shows the active code in plain text.

1.1Status LED

LEDFlashingSolid
GreenRemotely controlled & OKOK
BlueStarting upSleeping
OrangeSetup required / FW update in progressN/A
RedSystem faultHardware fault

When the SRX is first powered on, it runs a self-test and the LED flashes orange until a charge profile is configured. A red fault code is shown as a number of red flashes (Red Flash Codes, below).

1.2Not Starting or Sleeping

SymptomLikely causeCheckFix
No LED at allNo PV input: the SRX does not power up from the battery terminalPV isolator on; PV voltage at the SRX terminalsNormal at night. AERL Cloud shows an SRX as Sleeping overnight
Solid blue (sleeping), −1153 · −1158 Low input voltagePV voltage below minimum or below battery voltageThe SRX starts once the PV input is above 60 Vdc and at least 10 Vdc higher than the battery voltage. Normal at sunrise and sunsetConfirm the PV string configuration. Look for damaged or corroded PV connections and loose PV terminals
Flashing blue for about 60 s at start-upNormal start-up—The SRX then begins to charge

Start-up order: connect the battery first, then turn the PV isolator on. Shut down in reverse: PV isolator off first, wait for the LED to go out, then open the battery breaker. Never open the battery breaker under load.

AERL Field Troubleshooting GuideRev 1.0.0

1.3Orange LED: Setup or Charge Held

SymptomLikely causeCheckFix
Flashing orange, −26 Device not configuredInitial setup not completed; the SRX will not charge—Connect and configure the device with AERL Link
Flashing orange, −1160 Configuration out of rangeSet-point configuration outside limits for the detected nominal battery voltageThe charge profile against the battery manufacturer's recommendations, and the battery against the nominal battery voltage ranges in the manual's specificationsSet a charge profile appropriate for the battery in AERL Link. On a CAN-controlled system, also check the controller's targets against the BMS limits, then send Enable
Flashing orange, −1303 Waiting for CAN masterCAN-controlled mode, no commands from the master yet; the charger appears disabledThe CAN master is powered and sending commandsIf standalone operation is intended, disable CAN control in AERL Link
Flashing orange, −1301 CAN master lostNo setpoint update from the CAN master within the time-outThe RJ45 connection is secure and the master is still activeRestore the master's commands
Flashing orange, −1307 Charge held: battery current limitReported by some pre-release firmware—Contact AERL support
Flashing orange, 110 Firmware update in progressA firmware update is being installed over CAN—Wait. Do not remove power or the communications cable

1.4Charging Stopped or 0 W

SymptomLikely causeCheckFix
1 flash red, −360 No output detectedConverter enabled but no output current flowing—Power cycle. If it recurs, contact AERL
2 flashes red, −1159 Low output / no batteryNo battery detected, or output voltage implausibly lowBattery connected; output breaker closed; BMS has not shut the battery downReconnect the battery. To recharge a fully depleted bank from black, enable Blackstart Guard in AERL Link, and disable it once the bank has recovered (Chapter 08)
Flashing blue, −1162 Current flow interruptedCharge current stopped abruptly: a breaker opened or a cable was disconnectedPV and battery breakers, fuses and terminationsRestarts automatically. If it recurs, contact AERL
AERL Field Troubleshooting GuideRev 1.0.0
SymptomLikely causeCheckFix
3 flashes red, −1305 Battery BMS faultFault or alarm received from the battery's BMS over CANThe battery's own indicatorsFollow the battery manufacturer's manual (LiFe²: Chapter 03 of this guide)
Green, 0 W, no code, battery coldLow-Temperature Charge Cutoff enabled and the battery below its set pointBattery temperature against the cutoff set point in AERL LinkCharging resumes once the battery is above the set point
Green, 0 W, no code, CAN-controlledThe system controller has lowered the current limit, or its Power Targets stoppedThe controller (EMS) and its CAN busSee CAN Systems, below

The SRX does not charge until a charge profile is configured for the connected battery. AERL Link's live status shows the charging power (W) and a plain-text status with any active warning or fault.

1.5Earth (Ground) Faults

The SRX checks every connected pole for insulation degradation at start-up and trips a ground fault when the insulation resistance of a monitored pole falls below a fixed 50 kΩ (firmware 2.0.1 and later; earlier firmware offered a Low / Mid / High setting: update the firmware with AERL Link). The chassis must be connected to the same earth as the PV array. Check that 50 kΩ meets your local standards.

SymptomLikely causeCheckFix
Flashing blue, −1400 Possible earth faultAn earth-leakage reading at start-up was outside limits; the SRX re-tests before confirming. Charging continuesWhether the code recurs, or becomes −1401 · −1403If it does, inspect the wiring insulation
10 flashes red, −1401 · −1402 · −1403 Earth fault detectedEarth fault on the input or outputIsolate the controller and confirm the fault with an insulation resistance testerRepair the fault before recommissioning
Earth fault on a system with one pole bonded to earthGround Fault Mode left on FloatingThe system earthing against the Ground Fault Mode in AERL LinkSet Positive Earth or Negative Earth to match the bonded pole. A wrong mode masks a genuine fault or trips on the earthed pole

On a CAN-controlled system, treat an earth fault as a latched critical alarm: the SRX may keep charging, and its flag can clear before the fault is fixed.

AERL Field Troubleshooting GuideRev 1.0.0

1.6Red Flash Codes

Red LEDCodeFaultFirst action
Solid−1 to −99 (not −26)Generic hardware faultPower cycle. If persistent, contact AERL for warranty replacement
Solid−150Measurement faultPower cycle. If persistent, contact AERL
Solid−350 · −1055 · −1161Temperature sensor faultCheck the communications wiring and connected devices (a Battery Sense, Chapter 07)
Solid−365 · −370 · −380 · −390Startup / precharge faultPower cycle. Check PV and battery isolators, breakers and wiring
Solid−367 · −368 · −369 · −371 · −372 · −400 · −401Critical system faultPower cycle; check comms wiring and power-supply integrity
Solid−1050 to −1054Active cooling faultCheck the fan for blockages, then power cycle
Solid−1100Internal temperature criticalRestarts when safe. Ensure clearance and ventilation
Solid−1163Current sensor faultPower cycle. If persistent, contact AERL
1 flash−360No output detectedSee Charging Stopped or 0 W
2 flashes−1159Low output / no batterySee Charging Stopped or 0 W
3 flashes−1154High output voltageBattery may be charged from a secondary source: confirm charge parameters across the system
3 flashes−1155High battery voltageVerify the battery nominal voltage matches the configured profile
3 flashes−1305Battery BMS faultSee the battery manufacturer's manual
4 flashes−1157High output currentConfirm no short on the output and the load is within the current limit
5 flashes−1152High PV voltageConfirm string Voc at record-low ambient is within the rating
6 flashes−1156High PV currentConfirm the string configuration suits the device
8 flashes−1102High battery temperatureIncrease temperature compensation in AERL Link or reduce ambient
9 flashes−1103Low battery temperatureConsider a temperature-controlled battery environment
10 flashes−1401 · −1402 · −1403Earth fault detectedSee Earth (Ground) Faults
AERL Field Troubleshooting GuideRev 1.0.0

If a fault persists after these actions, contact AERL on 1800 950 865 or [email protected].

1.7CAN Systems: Units Stop With No Code

Most SRX faults clear themselves: the SRX restarts once the condition has cleared, after a hold-off of 10 s to 30 min. If the flags read 0 and the units show output off with no current, work through these checks (SRX CAN Integration Guide, available from AERL on request):

#CauseWhat to do
1The controller's Power Targets stopped or arrived late (after 34 s without one the SRX returns to default behaviour)Review the EMS. Units resume when the next target is received
2A Shutdown was sent, or another unit's fault turned the bus offSend Enable. If units don't resume, send Reset (Reset restarts every SRX on the bus)
3The battery BMS is alarmingClear the BMS alarm, then send Reset if units don't resume
4Routine self-restartNormal. Ignore a single short dropout
5None of the aboveContact AERL with the unit's event log

Throttle charging with the current limit, not the voltage target: a voltage target below the battery voltage raises High output voltage (−1154 · −1155).

1.8Firmware Updates

Update over USB with AERL Link. Keep the SRX connected to its battery and powered, and do not disconnect USB, remove power or open the isolators during the update. If an update fails partway, retry: the SRX keeps its previous valid firmware and runs normally until a complete update is received. On the SRX-R, set the MPPT 1 / MPPT 2 selector to the module you are updating, and repeat for the other module.

AERL Field Troubleshooting GuideRev 1.0.0
02

Nexus GatewayStatus in AERL Cloud, gateway faults, devices missing or offline

The Nexus is monitored from AERL Cloud, which shows its online status, last-seen time, firmware version and connection history. It needs no user action in normal operation and applies firmware updates when AERL publishes them.

2.1Status in AERL Cloud

A gateway shows Online (it has reported in the last 15 minutes) or Offline. The equipment on a gateway shows one of four statuses:

Equipment statusMeaning
OnlineThe device has reported in the last 15 minutes
SleepingAn SRX that has not reported for between 15 minutes and 24 hours: normal overnight
OfflineSilent for more than 15 minutes (more than 24 hours for an SRX)
InactiveNever reported, or silent for more than 30 days

2.2Gateway Faults

SymptomLikely causeCheckFix
Nexus does not power upNo supply, or a supply out of rangeDC input within 12–60 Vdc and polarity correct, or the supplied 5 V USB-C plug fully seated. Use only one input at a timeCorrect the supply
Powers up but never appears onlineNo internet path, or not claimedThe Ethernet cable goes to a port with internet access; outbound HTTPS (port 443) is allowed; the right serial number was claimedCorrect the network or the claim. If it still does not come online, contact AERL support with the Nexus serial number
Online, then goes offlineNetwork outage or firewall egress rulesThe Last Seen time in AERL Cloud; the site network or mobile connectionThe Nexus retries automatically and uploads its buffered data when it reconnects
AERL Field Troubleshooting GuideRev 1.0.0
SymptomLikely causeCheckFix
Data arrives only every ten minutesCellular connection—Normal: the Nexus sends data every minute over Ethernet and every ten minutes over cellular
Random comms dropoutsNetwork, or cablingThe Nexus status, Last Seen time and firmware version in AERL CloudContact AERL support with the Nexus serial number and the times it dropped out

2.3Devices Missing or Offline

SymptomLikely causeCheckFix
Nexus online, no devices discoveredWiring, termination or powerCAN devices on CAN 1 or CAN 2; the bus terminated at both ends; every device powered; the device is a supported AERL profileCorrect the wiring or termination
A device shows OfflineIts gateway is offline, or cabling, termination or powerThe gateway first; then connections, CAN or RS485 termination and damaged cables; that the device is powered; Modbus address and settings on the gatewayFix the gateway or wiring. An SRX showing Sleeping at night is normal
A device is missing from the listNot reported in the last 30 days, wrong location, or accessChoose Inactive in the status menu; the gateway is online and at the right location; your user group's locationsRe-assign the gateway's location
Readings are intermittentCable quality, shielding or terminationShielded cable, data cables kept away from power cables, bus terminationContact AERL support with the serial number and the times data was missing

2.4CAN Bus and Termination

The Nexus CAN sockets are linked inside the Nexus (one CAN interface, two sockets), and the Nexus has no built-in termination. A CAN bus needs 120 Ω at each of its two ends and nothing in between:

AERL Field Troubleshooting GuideRev 1.0.0

2.5Selectronic SP PRO over RS485

The Nexus has two status LEDs beside its RS485 socket: Tx flickers when the Nexus sends a Modbus request, Rx when the SP PRO replies.

Nexus LEDsCheck
Tx not flickeringThe Nexus is not polling: check it is online in AERL Cloud and that the Modbus device entry exists
Tx flickers, Rx does notThe SP PRO is not replying: cable in Port 1 on the ACC, a straight-through ethernet cable, the ACC power LED on; then the slave address, baud rate and format, Modbus saved as enabled in SP LINK, SP PRO firmware
Both flicker, no data in AERL CloudThe cloud configuration does not match the SP PRO: slave ID, baud rate and the product profile in Edit Gateway

The Nexus must be the only Modbus master on the SP PRO's RS485 port.

AERL Field Troubleshooting GuideRev 1.0.0
03

LiFe² 5120SBattery LEDs, common faults, recovering a flat battery

3.1Battery LEDs

LEDStatusDescription
ErrorRed onAn error has occurred
ErrorOffThere are no active errors
StatusGreen onThe battery is active and can be charged and discharged
StatusFlashes slowlySelf-Managed (no comms) mode
StatusOffThe battery is not active
SOC4 / 3 / 2 / 1 LEDs on75–100% / 50–75% / 25–50% / 0–25% SOC

Below 5% SOC the first SOC LED flashes quickly (1 Hz). While discharging the last lit LED flashes at 0.5 Hz; while charging it flashes slowly, at 0.25 Hz.

3.2Common Faults

SymptomLikely causeCheckFix
Error LED onA battery errorNote the battery state (LEDs, inverter display)Contact AERL support
Inverter shows no battery communicationComms cable or pin mappingThe cable is in COMM on the master battery, not IN or OUT; only the master connects to the inverter; the cable is undamaged, seated, no longer than 5 m, shielded Cat 5 or better, with the pin mapping for your inverter (battery CAN_H / CAN_L on pins 4 / 5)Correct the cable; see Inverter Messages, below
Some batteries missing or not workingLink chainEach OUT connects to the next battery's IN; the termination plug is in OUT of the last batteryTry another link cable
Status LED flashes slowlySelf-Managed modeThe comms cable to the inverterThe battery returns to Managed mode when the cable is connected
AERL Field Troubleshooting GuideRev 1.0.0
SymptomLikely causeCheckFix
SOC shown by the inverter driftsNo recent full chargeWhen the system last reached 100% SOCCharge to 100%: at least every 14 days (Self-Managed) or 30 days (Managed), and at first start-up
Battery shut itself down after a long period without chargingLow SOC protection—Recharge it within 10 days to restore the SOC
Battery breaker offSwitched off, or tripped by the BMS on a fault (overcurrent, short circuit, overvoltage, over-discharge or an internal fault)The DC cabling for damage or a short; the Error LEDClear the cause before switching it on. If it trips again with no external cause, contact AERL support
Still not working——Restart in order (below)

Restart in order: shut down the inverter; turn off the DC breaker between battery and inverter; hold ON/OFF on the master battery for 3 seconds; wait until all LEDs are off, then 3 minutes more; turn the DC breaker on; press ON/OFF for 1 second; start the inverter.

3.3Recovering a Flat Battery

If a battery module reaches 0% SOC and its voltage falls below 40 V (over-discharge), recharge it in one of these ways:

  1. If the inverter still operates, charge the battery from the inverter.
  2. Connect a module at a higher voltage in parallel: it balances and charges the flat module automatically.
  3. If inverter charging is not possible, use a 48 V adjustable constant-current charger set to 54 V and no more than 10 A. Charge for at least 30 minutes.

A battery stored for 6 months or more: if its voltage is above 51.6 V it needs no charge (check it every 3 months); below 51.6 V, charge it at 55 V DC and a constant 10 A for at least 30 minutes. If a battery has been submerged in water, stop using it and contact AERL.

AERL Field Troubleshooting GuideRev 1.0.0

3.4Inverter Messages (Managed Mode)

InverterMessage or symptomCheck
VictronBattery not in the Device ListType A cable, CAN-bus BMS end at the battery, in the BMS-Can port (or a VE.Can port set to CAN-bus BMS LV (500 kbit/s)); the terminator fitted at the GX device. The battery shows as Pylontech
Victron"BMS connection lost", inverter shuts downRestore the connection, then restart the inverter/charger. A low battery voltage alarm at the same time is caused by the lost communication
Deyecomm./FXX; Li-BMS page emptyCable in the BMS port and in COMM on the master battery; Batt Mode Lithium; Lithium Mode 00
DeyeFault F58Communication lost while BMS_Err_Stop is active: check the cable, then restart the system in order
Selectronic SP PROBeeping; CAN bus Comms LED on steadilyThe BMS to SP PRO CAN bus cable (pins 1 / 2 at the SP PRO, 4 / 5 at the battery), not a straight-through lead
Selectronic SP PROBattery Management values blankBattery type AERL LiFe2-5120S selected and saved; SP PRO firmware 16.11 or later, comms card 5.31 or later; restart the battery DC supply
Selectronic SP PROIntermittent communication; multi-phase not readingComms card CAN termination DIP switch ON; CAN cable to the L1 SP PRO only
SolisCAN FailPins 4 and 5 at both ends; cable in COMM; Battery Model Lithium Battery LV, not the RS485 variant
SolisBatName-FAIL / NO-BatteryBattery Model selection / DC breakers on and the battery on

Full settings: LiFe² 5120S Managed Battery Integration Guide.

AERL Field Troubleshooting GuideRev 1.0.0
04

Kakadu 120HMI indicators, common faults

Kakadu 120 needs an AERL Nexus Gateway to manage the battery communications. Each cabinet holds two independent strings, each with its own BMS and HMI, so the system keeps operating if one string faults.

4.1HMI Indicators

IndicatorNormalOtherwise
RunGreen: power onOff: power off
AlarmOffOrange: a serious fault, such as over-voltage or over-current
Module status 1–4Off: module workingNumber lit orange: that module has failed. Indicators 5–9 are not used
SOC1–5 bars, 20% eachLast bar flashes 1 Hz discharging, 0.5 Hz charging
Master UnitLit on the master string onlyLit on every string by default: press it on each string that is not the master
Last UnitLit on the last string onlyLit on every string by default: press it on each of the other strings
Black StartOffGreen: black start on (off-grid start)

4.2Common Faults

SymptomLikely causeCheckFix
Alarm orangeA serious fault, such as over-voltage or over-currentThe working logs, cell voltages and module temperatures through the Nexus in AERL CloudNote the HMI state and contact AERL support
A module number lit orangeThat module has failed—Contact AERL support with the cabinet and string
Run offString not started, or shut downThe MCB on each BMS is on (shutting down trips it automatically)Turn on each BMS's MCB, then press its ON/OFF button
AERL Field Troubleshooting GuideRev 1.0.0
SymptomLikely causeCheckFix
Inverter does not see the battery, or reports the wrong capacityMaster Unit, Last Unit or the comms chainMaster Unit lit on the master string only; Last Unit lit on the final string only; OUT of each BMS to IN of the next; a terminating resistor on COM2 of the last module of every string; INV of the master BMS on the CAN busCorrect and confirm every string's Run is lit and the inverter reports the combined capacity
Selectronic SP PRO shows no Kakadu dataCable pins or terminationThe SP PRO to BMS cable (CAN on pins 4 and 5 at the BMS end; a straight-through patch lead will not work; cables made to the commissioning guide's Rev 1.1.5 or earlier used the wrong pins); the SP PRO CAN termination DIP switch ON; every SRX's CANBUS 120 Ω switch OFF; no plug at a mid-bus NexusBattery type BMS – SelectCell River Gum in SP LINK; Data View → Battery Management shows the BMS data
Off-grid system will not startThe inverter needs the battery to start—Power up the system, then hold Black Start for three seconds

Full procedures: Kakadu 120 Installation and Operating Manual (chapters 5–8) and the Kakadu Commissioning Guide, SP PRO SPLC1202 & CoolMax SRX.

AERL Field Troubleshooting GuideRev 1.0.0
05

EarthGuard EG‑600 and EG‑600‑SCLEDs and buzzer, common faults, finding an earth fault

5.1LEDs and Buzzer

EG-600 (two circuits):

ConditionAll ClearCircuit 1 faultCircuit 2 faultBuzzer
All Clear (insulation OK)OnOffOffOff
Circuit 1 earth fault (DC+ or DC−)OffOnOffPulsing
Circuit 2 earth fault (DC+ or DC−)OffOffOnPulsing

All Clear is green and the Circuit Fault LEDs are red. In a fault the buzzer sounds for about 1.5 s, then is silent for 1.5 s, until the fault clears.

EG-600-SC (one circuit):

All Clear (green)Fault (red)Meaning
Solid onOffNormal operation
OffFlashing (2 Hz)Warning: a possible fault has been measured and is being confirmed. Relay and buzzer not yet active
OffSolid onConfirmed earth fault: the buzzer sounds and the alarm relay opens

Both return to All Clear, and close their relays, by themselves once the insulation resistance is back above the trip threshold.

5.2Common Faults

SymptomLikely causeCheckFix
Fault LED on, buzzer soundingAn earth fault below the trip thresholdFind the fault (below)Repair it; the unit returns to All Clear
No LED litNo supplySupply 12–60 Vdc at the input, from a current-limited power supply, not a battery directly. EG-600-SC: the BATT/PSU jumper fitted only for a 12–15 Vdc supplyCorrect the supply. Never fit the BATT/PSU jumper above 15 Vdc
AERL Field Troubleshooting GuideRev 1.0.0
SymptomLikely causeCheckFix
External monitor alarms, EarthGuard shows All ClearThe relay is fail-safe: it opens on an earth fault, a loss of power or a broken cable alikeThe relay wiring to the monitor; the EarthGuard's supplyRepair the wiring or supply
Fault on a circuit with one pole bonded to earth (EG-600)Ground fault mode on FloatingThe circuit's ground fault mode in AERL LinkPositive Earth or Negative Earth, only if that pole is deliberately and permanently bonded to earth
Trips at a level you did not expectTrip thresholdOn firmware 2.2.1 the trip threshold is fixed at 30 kΩ; the sensitivity setting applies on later firmwareCheck that 30 kΩ meets your local standards; if it does not, contact AERL
AERL Link shows an internal self-test fault (EG-600)Device fault—Contact AERL support

5.3Finding an Earth Fault

  1. Prepare. Wear PPE (insulated gloves, safety glasses), follow your isolation procedure and use rated test equipment.
  2. Shut down. Turn off the inverter and charge controllers, open the battery breakers and PV array isolators, power down the EarthGuard, and confirm zero voltage with a multimeter.
  3. Inspect. Look for damaged cables (including rodent damage) and degraded PV module back sheets.
  4. Segment and test. Measure the resistance to earth of the battery conductors, then of the PV array conductors.
  5. Repair and restart. Fix the fault and restore power.
AERL Field Troubleshooting GuideRev 1.0.0

5.4Testing the EarthGuard

Caution — potential hazard

An earth fault can damage power conversion equipment (PCE) and connected components. Ask the PCE manufacturer before you simulate an earth fault. AERL takes no responsibility for damage caused by simulating an earth fault.

With the system isolated and the EarthGuard powered down, fit a 10–12 kΩ resistor (20 kΩ maximum; not supplied) between the + or − terminal of the circuit under test and the Earth terminal. Reconnect the battery, restore power and confirm the fault is reported (EG-600-SC: wait 15 seconds): Fault LED, buzzer, relay open. Power down, remove the resistor and reconnect. If nothing trips, check the EarthGuard is powered (one LED lit) and that you can measure the resistor, then repeat. The full procedure is in Chapter 08 of each user manual.

AERL Field Troubleshooting GuideRev 1.0.0
06

CoolPro CP30Indicators, common faults, Modbus communication

6.1Indicators

The Input Alive LED lights when the input breakers are closed. The Output Alive LED lights when the CoolPro is delivering output. The LCD alternates between the input and output measurements every 5 seconds, each with its voltage, current and the board temperature.

6.2Common Faults

SymptomLikely causeCheckFix
Input Alive on, Output Alive offAll setpoints at zeroThe three front-panel dialsSet the voltage, reference cell and current dials as in the setpoint procedure (Chapter 07)
Input Alive on, Output Alive offLow-battery cut-outBattery voltage against the cut-out for the selected nominal voltage (12 V: 11 V / 13 V; 24 V: 22 V / 26 V; 36 V: 33 V / 39 V; 48 V: 44 V / 52 V, cut-out / cut-in) and the battery voltage selectorRecharge the battery; press Low Batt Reset to cut back in at any voltage above the cut-out
Input Alive on, Output Alive offCurrent interrupt terminals linkedThe current interrupt terminals (Link On/Off) and any interrupt sequencerLinked, the output is off: remove the link
Input Alive offNo inputInput breakers closed; battery voltage and polarity at the terminalsCorrect the supply. If the battery is correct at the terminals, contact AERL
Output current below the Current dial settingAnother control mode is limiting: the voltage limit (ground bed resistance rises in dry periods) or the reference cellWhich dial is limitingRaise that mode's dial until the current control mode limits again
Output breaker trips in stormsSurge currents shunted by the surge protectionWhether an output breaker or fuse is fittedAn output breaker or fuse is not recommended: remove it
AERL Field Troubleshooting GuideRev 1.0.0
SymptomLikely causeCheckFix
Lightning damage on a long pipeline or tall structureNo Surge BusterStructure longer than 100 m or higher than 10 mFit an AERL Surge Buster: it is required there
Readings driftCalibrationStatus flags (below)Recalibration is a workshop operation: contact AERL

Shut the CoolPro down in this order: turn all three dials fully anti-clockwise, check the LCD shows zero output for 10 seconds (Output Alive turns off), then open the input breakers.

6.3Modbus Communication

SymptomCheck
No responseStation address 40 and 9600 baud, 8-N-1 (factory defaults); RJ45 pins 3 (A), 6 (B) and 8 (GND) only; 120 Ω termination at both ends of the bus. A changed address or baud rate takes effect after a reset
Register 40003 always reads 0Normal: it is a write-only command trigger
Setpoints do not change over ModbusNormal: the meter board is a monitoring path only. Output current, voltage limit and reference-cell setpoint are set on the front panel

Status flags (register 30008): bit 2 input or bit 3 output measurement fault, bit 4 calibration invalid, bit 5 calibration missing, bit 6 temperature sensor fault. Contact AERL if any of these is set; bits 0 (startup) and 1 (daily reset) are normal.

AERL Field Troubleshooting GuideRev 1.0.0
07

Battery SenseLEDs, common faults

7.1LEDs

LEDStateMeaning
Green (Active)Slow heartbeat (brief flash every ~1.5 s)Device is powered and operating normally
Green (Active)OffDevice is not powered
Red (Fault)Solid onFault condition detected (e.g. watchdog initialisation failure)
Red (Fault)Brief 3× flashFloat event acknowledgement
Yellow (CAN activity)Brief blinkA CAN message has been transmitted or received
Yellow (CAN activity)OffNo CAN bus activity

At power-on all three LEDs light briefly as a self-test.

7.2Common Faults

SymptomPossible causesSolution
Green LED not flashing5 V power toggle on the SRX not enabled; poor connection to the SRX; faulty CAT6 cableTurn the SRX's 5 V power toggle ON; check cable connections; try a different CAT6 cable
Red Fault LED solid onInternal device fault; voltage sense connection; voltage out of rangePower-cycle the device; check the voltage sense connections; verify the battery is within 18–200 Vdc; contact AERL support
Yellow LED not blinkingNo CAN traffic; CAN bus configurationCheck cable connections; verify the 120 Ω termination switch positions; restart the SRX
AERL Field Troubleshooting GuideRev 1.0.0
SymptomPossible causesSolution
Temperature not showing in AERL Link120 Ω termination not enabled; communication issue; device faultSet the 120 Ω termination switch to ON; check cable connections; verify the green LED is lit
SRX solid red, −350 · −1055 · −1161, or Battery Sense LostThe SRX has lost the temperature readingThe CAT6 cable and the Battery Sense LEDs (above)
Incorrect voltage readingPoor voltage sense connection; improperly sized fuse; damaged sense wireCheck the voltage sense connections and fusing; inspect the wiring
Float switch input not workingImproper connection; external voltage appliedUse a normally open, voltage-free switch; apply no voltage; check the switch's continuity
Float indication output not workingOver the 12 V / 2 A rating; blown fuse; connectionKeep the load within rating; check or replace the fuse; verify connections
AERL Field Troubleshooting GuideRev 1.0.0
08

Solinteg M2HT and All-In-OneInverter indicators, common inverter faults

The M2HT 25–50 inverter, also used in the All-In-One, shows each fault by name on its display; the All-In-One battery shows codes. Status codes (S01, S02 …) show the inverter's state and are not faults. Full lists: M2HT 25–50 user manual Chapter 08, All-In-One user manual section 7.3.

8.1Inverter Indicators

IndicatorColourStateMeaning
Power and alarmBlueFast flashing / slow flashing / breathingSelf-test / waiting / operating normally
Power and alarmOrangeBreathingLow battery: close to the SOC protection limit
Power and alarmRedOnAlarm or fault: check the display
Grid—Off / slow flashing / onGrid lost / grid detected, not on-grid / operating on-grid
CommunicationGreenOn / flashingNormal / communicating with an EMS or the master inverter
CommunicationOrangeOnNo communication with the smart meter
CommunicationRedOnNo communication with the BMS

8.2Common Inverter Faults

MessageWhat to do
Mains LostNo grid detected: check the grid voltage, AC wiring and AC breaker
Grid Voltage FaultCheck the grid code and AC wiring, and the AC cable size (voltage rise). Widen the limits only with the network service provider's permission
ISO Over LimitationLow DC insulation resistance to earth: check PV modules, batteries, DC cables and connectors for damage or water. It must be at least 500 kΩ
GFCI FaultExcessive earth leakage: check PV modules, batteries, DC cables and connectors for damage or water
PV Over VoltageReduce the modules per string so the open-circuit voltage is below the inverter's maximum
Over TemperatureCheck the ventilation; shut the inverter down to cool, then restart
N-PE Check FaultBack-up earth loose or poorly connected: check the earth wiring, or turn N-PE Check off if the bond is not needed
Backup Load FaultReduce the back-up load; check the battery's discharge capacity
AERL Field Troubleshooting GuideRev 1.0.0
MessageWhat to do
Meter Comm FaultCheck the meter communication cable and that the meter model is compatible
BMS Comm FaultCheck the battery ID setting, the BMS cable and the battery status
PV Power LowCheck the PV connection and generation, and the battery output
BAT Power Low, BAT InvalidCheck the battery cables, breaker, switch or fuse and any battery alarm; restart the battery

An earth fault on the PV array keeps the power indicator red and shows ISO Over Limitation or GFCI Fault until it is cleared; the app and portal show an alarm (email alerts can be set). Install the inverter where the indicator will be noticed.

8.3All-In-One Cabinet and Battery

Cabinet indicators: the audible and visual alarm sounds and flashes when the smoke sensor is triggered; Power (white) is on while grid power is present; Running (green) while the high-voltage box operates; Fault (red) when the cabinet has a fault. Check the alarm details in the monitoring data.

Battery codes starting with E are protection faults (the battery stops to protect itself); I are alarms and W warnings (the system keeps running).

CodeNameWhat to do
E400BMS communicationCheck the battery type selected in the inverter, the battery status, and the communication cable and its pinout
E401Low SOCCheck the battery's communication and power connections, the inverter's PV, grid and generator connections, and whether the load is too large
E403BMS sleepingCheck that the grid or PV can supply stable power for long enough, and the battery power connection
E416Insulation faultShut down the whole system; check equipment, cables and terminals for damage and short circuits; restart the battery
E417 / I400 / W400Cell undervoltageCheck the inverter allows forced charging and the external source is running; charge the battery immediately (E417: restart the battery first)
AERL Field Troubleshooting GuideRev 1.0.0
CodeNameWhat to do
E421 / I404 / W404Charge undertemperatureCheck the temperature reading is plausible and the sensors; warm the battery (E421: then restart the battery)
E431Battery voltage abnormalCheck the battery power cables for damage and any battery alarm or protection; clear the problem, then restart the battery
E432Battery parallel number abnormalCheck the target number of clusters, the communication between clusters and the inverter, and that every cluster is switched on, free of alarms and within 2.5 V of the others; then re-run the paralleling process
E425 / I408 / W408Charge overcurrentCheck whether the battery's current limit was reduced and the inverter is charging above it; correct the configuration, restart the battery

For any fault that persists after these checks, contact AERL support.

AERL Field Troubleshooting GuideRev 1.0.0
09

Support and ReturnsBefore you contact AERL, returning a product, change log

9.1Before You Contact AERL

Have ready:

Contact AERL support on 1800 950 865 or [email protected].

9.2Returning a Product

Email the AERL RMA form, with any photos or screenshots, to [email protected] with the serial number as the subject. AERL replies with a Return Materials Authorisation (RMA) number: do not send a product without one. Then send the product, with its RMA number, to AERL, 1/75 Bluestone Circuit, Seventeen Mile Rocks QLD 4073, Australia. For a battery, wait for AERL's shipping instructions before you send it: lithium batteries are dangerous goods. The full process is in the AERL Warranty Claims and Returns Guide.

Warranty terms are in each product's warranty statement, at aerl.com.au. Register a product's warranty at aerl.com.au/warranty-registration.

9.3Change Log

RevisionDateChange
1.0.011 / 2026First issue.
AERL Field Troubleshooting GuideRev 1.0.0

Thank You for Choosing AERL

If you have any questions or need support, contact AERL.

Sincerely,

The AERL Team

AERL Pty Ltd · 1/75 Bluestone Circuit, Seventeen Mile Rocks QLD 4073 · 1800 950 865 · [email protected] · aerl.com.au

AERL Field Troubleshooting GuideRev 1.0.0

Notes

AERL Field Troubleshooting GuideRev 1.0.0

Notes