Field Troubleshooting
Symptoms, Causes and Fixes Across the AERL Range
Symptoms, Causes and Fixes Across the AERL Range
This guide helps installers find and fix the faults most often met in the field on AERL products. It is organised by product, then by symptom. Each table gives what you see, its likely cause, what to check and the fix.
The guide summarises. Each product's user manual is the full reference: where a table names a chapter, it is the chapter of that product's manual. Use the latest manuals and software from aerl.com.au and aerl.com.au/professionals.
Only qualified people may test, open or rewire this equipment. Battery and PV circuits stay live when an inverter or controller is switched off, and a DC arc does not self-extinguish. Follow your isolation procedure, prove dead with a meter rated for the system voltage, and wear PPE.
The full list of warning and fault codes is in Chapter 13, Troubleshooting, of the CoolMax SRX and SRX-R user manuals. AERL Link (aerl.com.au/professionals) shows the active code in plain text.
| LED | Flashing | Solid |
|---|---|---|
| Green | Remotely controlled & OK | OK |
| Blue | Starting up | Sleeping |
| Orange | Setup required / FW update in progress | N/A |
| Red | System fault | Hardware fault |
When the SRX is first powered on, it runs a self-test and the LED flashes orange until a charge profile is configured. A red fault code is shown as a number of red flashes (Red Flash Codes, below).
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| No LED at all | No PV input: the SRX does not power up from the battery terminal | PV isolator on; PV voltage at the SRX terminals | Normal at night. AERL Cloud shows an SRX as Sleeping overnight |
| Solid blue (sleeping), −1153 · −1158 Low input voltage | PV voltage below minimum or below battery voltage | The SRX starts once the PV input is above 60 Vdc and at least 10 Vdc higher than the battery voltage. Normal at sunrise and sunset | Confirm the PV string configuration. Look for damaged or corroded PV connections and loose PV terminals |
| Flashing blue for about 60 s at start-up | Normal start-up | — | The SRX then begins to charge |
Start-up order: connect the battery first, then turn the PV isolator on. Shut down in reverse: PV isolator off first, wait for the LED to go out, then open the battery breaker. Never open the battery breaker under load.
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Flashing orange, −26 Device not configured | Initial setup not completed; the SRX will not charge | — | Connect and configure the device with AERL Link |
| Flashing orange, −1160 Configuration out of range | Set-point configuration outside limits for the detected nominal battery voltage | The charge profile against the battery manufacturer's recommendations, and the battery against the nominal battery voltage ranges in the manual's specifications | Set a charge profile appropriate for the battery in AERL Link. On a CAN-controlled system, also check the controller's targets against the BMS limits, then send Enable |
| Flashing orange, −1303 Waiting for CAN master | CAN-controlled mode, no commands from the master yet; the charger appears disabled | The CAN master is powered and sending commands | If standalone operation is intended, disable CAN control in AERL Link |
| Flashing orange, −1301 CAN master lost | No setpoint update from the CAN master within the time-out | The RJ45 connection is secure and the master is still active | Restore the master's commands |
| Flashing orange, −1307 Charge held: battery current limit | Reported by some pre-release firmware | — | Contact AERL support |
| Flashing orange, 110 Firmware update in progress | A firmware update is being installed over CAN | — | Wait. Do not remove power or the communications cable |
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| 1 flash red, −360 No output detected | Converter enabled but no output current flowing | — | Power cycle. If it recurs, contact AERL |
| 2 flashes red, −1159 Low output / no battery | No battery detected, or output voltage implausibly low | Battery connected; output breaker closed; BMS has not shut the battery down | Reconnect the battery. To recharge a fully depleted bank from black, enable Blackstart Guard in AERL Link, and disable it once the bank has recovered (Chapter 08) |
| Flashing blue, −1162 Current flow interrupted | Charge current stopped abruptly: a breaker opened or a cable was disconnected | PV and battery breakers, fuses and terminations | Restarts automatically. If it recurs, contact AERL |
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| 3 flashes red, −1305 Battery BMS fault | Fault or alarm received from the battery's BMS over CAN | The battery's own indicators | Follow the battery manufacturer's manual (LiFe²: Chapter 03 of this guide) |
| Green, 0 W, no code, battery cold | Low-Temperature Charge Cutoff enabled and the battery below its set point | Battery temperature against the cutoff set point in AERL Link | Charging resumes once the battery is above the set point |
| Green, 0 W, no code, CAN-controlled | The system controller has lowered the current limit, or its Power Targets stopped | The controller (EMS) and its CAN bus | See CAN Systems, below |
The SRX does not charge until a charge profile is configured for the connected battery. AERL Link's live status shows the charging power (W) and a plain-text status with any active warning or fault.
The SRX checks every connected pole for insulation degradation at start-up and trips a ground fault when the insulation resistance of a monitored pole falls below a fixed 50 kΩ (firmware 2.0.1 and later; earlier firmware offered a Low / Mid / High setting: update the firmware with AERL Link). The chassis must be connected to the same earth as the PV array. Check that 50 kΩ meets your local standards.
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Flashing blue, −1400 Possible earth fault | An earth-leakage reading at start-up was outside limits; the SRX re-tests before confirming. Charging continues | Whether the code recurs, or becomes −1401 · −1403 | If it does, inspect the wiring insulation |
| 10 flashes red, −1401 · −1402 · −1403 Earth fault detected | Earth fault on the input or output | Isolate the controller and confirm the fault with an insulation resistance tester | Repair the fault before recommissioning |
| Earth fault on a system with one pole bonded to earth | Ground Fault Mode left on Floating | The system earthing against the Ground Fault Mode in AERL Link | Set Positive Earth or Negative Earth to match the bonded pole. A wrong mode masks a genuine fault or trips on the earthed pole |
On a CAN-controlled system, treat an earth fault as a latched critical alarm: the SRX may keep charging, and its flag can clear before the fault is fixed.
| Red LED | Code | Fault | First action |
|---|---|---|---|
| Solid | −1 to −99 (not −26) | Generic hardware fault | Power cycle. If persistent, contact AERL for warranty replacement |
| Solid | −150 | Measurement fault | Power cycle. If persistent, contact AERL |
| Solid | −350 · −1055 · −1161 | Temperature sensor fault | Check the communications wiring and connected devices (a Battery Sense, Chapter 07) |
| Solid | −365 · −370 · −380 · −390 | Startup / precharge fault | Power cycle. Check PV and battery isolators, breakers and wiring |
| Solid | −367 · −368 · −369 · −371 · −372 · −400 · −401 | Critical system fault | Power cycle; check comms wiring and power-supply integrity |
| Solid | −1050 to −1054 | Active cooling fault | Check the fan for blockages, then power cycle |
| Solid | −1100 | Internal temperature critical | Restarts when safe. Ensure clearance and ventilation |
| Solid | −1163 | Current sensor fault | Power cycle. If persistent, contact AERL |
| 1 flash | −360 | No output detected | See Charging Stopped or 0 W |
| 2 flashes | −1159 | Low output / no battery | See Charging Stopped or 0 W |
| 3 flashes | −1154 | High output voltage | Battery may be charged from a secondary source: confirm charge parameters across the system |
| 3 flashes | −1155 | High battery voltage | Verify the battery nominal voltage matches the configured profile |
| 3 flashes | −1305 | Battery BMS fault | See the battery manufacturer's manual |
| 4 flashes | −1157 | High output current | Confirm no short on the output and the load is within the current limit |
| 5 flashes | −1152 | High PV voltage | Confirm string Voc at record-low ambient is within the rating |
| 6 flashes | −1156 | High PV current | Confirm the string configuration suits the device |
| 8 flashes | −1102 | High battery temperature | Increase temperature compensation in AERL Link or reduce ambient |
| 9 flashes | −1103 | Low battery temperature | Consider a temperature-controlled battery environment |
| 10 flashes | −1401 · −1402 · −1403 | Earth fault detected | See Earth (Ground) Faults |
If a fault persists after these actions, contact AERL on 1800 950 865 or [email protected].
Most SRX faults clear themselves: the SRX restarts once the condition has cleared, after a hold-off of 10 s to 30 min. If the flags read 0 and the units show output off with no current, work through these checks (SRX CAN Integration Guide, available from AERL on request):
| # | Cause | What to do |
|---|---|---|
| 1 | The controller's Power Targets stopped or arrived late (after 34 s without one the SRX returns to default behaviour) | Review the EMS. Units resume when the next target is received |
| 2 | A Shutdown was sent, or another unit's fault turned the bus off | Send Enable. If units don't resume, send Reset (Reset restarts every SRX on the bus) |
| 3 | The battery BMS is alarming | Clear the BMS alarm, then send Reset if units don't resume |
| 4 | Routine self-restart | Normal. Ignore a single short dropout |
| 5 | None of the above | Contact AERL with the unit's event log |
Throttle charging with the current limit, not the voltage target: a voltage target below the battery voltage raises High output voltage (−1154 · −1155).
Update over USB with AERL Link. Keep the SRX connected to its battery and powered, and do not disconnect USB, remove power or open the isolators during the update. If an update fails partway, retry: the SRX keeps its previous valid firmware and runs normally until a complete update is received. On the SRX-R, set the MPPT 1 / MPPT 2 selector to the module you are updating, and repeat for the other module.
The Nexus is monitored from AERL Cloud, which shows its online status, last-seen time, firmware version and connection history. It needs no user action in normal operation and applies firmware updates when AERL publishes them.
A gateway shows Online (it has reported in the last 15 minutes) or Offline. The equipment on a gateway shows one of four statuses:
| Equipment status | Meaning |
|---|---|
| Online | The device has reported in the last 15 minutes |
| Sleeping | An SRX that has not reported for between 15 minutes and 24 hours: normal overnight |
| Offline | Silent for more than 15 minutes (more than 24 hours for an SRX) |
| Inactive | Never reported, or silent for more than 30 days |
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Nexus does not power up | No supply, or a supply out of range | DC input within 12–60 Vdc and polarity correct, or the supplied 5 V USB-C plug fully seated. Use only one input at a time | Correct the supply |
| Powers up but never appears online | No internet path, or not claimed | The Ethernet cable goes to a port with internet access; outbound HTTPS (port 443) is allowed; the right serial number was claimed | Correct the network or the claim. If it still does not come online, contact AERL support with the Nexus serial number |
| Online, then goes offline | Network outage or firewall egress rules | The Last Seen time in AERL Cloud; the site network or mobile connection | The Nexus retries automatically and uploads its buffered data when it reconnects |
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Data arrives only every ten minutes | Cellular connection | — | Normal: the Nexus sends data every minute over Ethernet and every ten minutes over cellular |
| Random comms dropouts | Network, or cabling | The Nexus status, Last Seen time and firmware version in AERL Cloud | Contact AERL support with the Nexus serial number and the times it dropped out |
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Nexus online, no devices discovered | Wiring, termination or power | CAN devices on CAN 1 or CAN 2; the bus terminated at both ends; every device powered; the device is a supported AERL profile | Correct the wiring or termination |
| A device shows Offline | Its gateway is offline, or cabling, termination or power | The gateway first; then connections, CAN or RS485 termination and damaged cables; that the device is powered; Modbus address and settings on the gateway | Fix the gateway or wiring. An SRX showing Sleeping at night is normal |
| A device is missing from the list | Not reported in the last 30 days, wrong location, or access | Choose Inactive in the status menu; the gateway is online and at the right location; your user group's locations | Re-assign the gateway's location |
| Readings are intermittent | Cable quality, shielding or termination | Shielded cable, data cables kept away from power cables, bus termination | Contact AERL support with the serial number and the times data was missing |
The Nexus CAN sockets are linked inside the Nexus (one CAN interface, two sockets), and the Nexus has no built-in termination. A CAN bus needs 120 Ω at each of its two ends and nothing in between:
The Nexus has two status LEDs beside its RS485 socket: Tx flickers when the Nexus sends a Modbus request, Rx when the SP PRO replies.
| Nexus LEDs | Check |
|---|---|
| Tx not flickering | The Nexus is not polling: check it is online in AERL Cloud and that the Modbus device entry exists |
| Tx flickers, Rx does not | The SP PRO is not replying: cable in Port 1 on the ACC, a straight-through ethernet cable, the ACC power LED on; then the slave address, baud rate and format, Modbus saved as enabled in SP LINK, SP PRO firmware |
| Both flicker, no data in AERL Cloud | The cloud configuration does not match the SP PRO: slave ID, baud rate and the product profile in Edit Gateway |
The Nexus must be the only Modbus master on the SP PRO's RS485 port.
| LED | Status | Description |
|---|---|---|
| Error | Red on | An error has occurred |
| Error | Off | There are no active errors |
| Status | Green on | The battery is active and can be charged and discharged |
| Status | Flashes slowly | Self-Managed (no comms) mode |
| Status | Off | The battery is not active |
| SOC | 4 / 3 / 2 / 1 LEDs on | 75–100% / 50–75% / 25–50% / 0–25% SOC |
Below 5% SOC the first SOC LED flashes quickly (1 Hz). While discharging the last lit LED flashes at 0.5 Hz; while charging it flashes slowly, at 0.25 Hz.
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Error LED on | A battery error | Note the battery state (LEDs, inverter display) | Contact AERL support |
| Inverter shows no battery communication | Comms cable or pin mapping | The cable is in COMM on the master battery, not IN or OUT; only the master connects to the inverter; the cable is undamaged, seated, no longer than 5 m, shielded Cat 5 or better, with the pin mapping for your inverter (battery CAN_H / CAN_L on pins 4 / 5) | Correct the cable; see Inverter Messages, below |
| Some batteries missing or not working | Link chain | Each OUT connects to the next battery's IN; the termination plug is in OUT of the last battery | Try another link cable |
| Status LED flashes slowly | Self-Managed mode | The comms cable to the inverter | The battery returns to Managed mode when the cable is connected |
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| SOC shown by the inverter drifts | No recent full charge | When the system last reached 100% SOC | Charge to 100%: at least every 14 days (Self-Managed) or 30 days (Managed), and at first start-up |
| Battery shut itself down after a long period without charging | Low SOC protection | — | Recharge it within 10 days to restore the SOC |
| Battery breaker off | Switched off, or tripped by the BMS on a fault (overcurrent, short circuit, overvoltage, over-discharge or an internal fault) | The DC cabling for damage or a short; the Error LED | Clear the cause before switching it on. If it trips again with no external cause, contact AERL support |
| Still not working | — | — | Restart in order (below) |
Restart in order: shut down the inverter; turn off the DC breaker between battery and inverter; hold ON/OFF on the master battery for 3 seconds; wait until all LEDs are off, then 3 minutes more; turn the DC breaker on; press ON/OFF for 1 second; start the inverter.
If a battery module reaches 0% SOC and its voltage falls below 40 V (over-discharge), recharge it in one of these ways:
A battery stored for 6 months or more: if its voltage is above 51.6 V it needs no charge (check it every 3 months); below 51.6 V, charge it at 55 V DC and a constant 10 A for at least 30 minutes. If a battery has been submerged in water, stop using it and contact AERL.
| Inverter | Message or symptom | Check |
|---|---|---|
| Victron | Battery not in the Device List | Type A cable, CAN-bus BMS end at the battery, in the BMS-Can port (or a VE.Can port set to CAN-bus BMS LV (500 kbit/s)); the terminator fitted at the GX device. The battery shows as Pylontech |
| Victron | "BMS connection lost", inverter shuts down | Restore the connection, then restart the inverter/charger. A low battery voltage alarm at the same time is caused by the lost communication |
| Deye | comm./FXX; Li-BMS page empty | Cable in the BMS port and in COMM on the master battery; Batt Mode Lithium; Lithium Mode 00 |
| Deye | Fault F58 | Communication lost while BMS_Err_Stop is active: check the cable, then restart the system in order |
| Selectronic SP PRO | Beeping; CAN bus Comms LED on steadily | The BMS to SP PRO CAN bus cable (pins 1 / 2 at the SP PRO, 4 / 5 at the battery), not a straight-through lead |
| Selectronic SP PRO | Battery Management values blank | Battery type AERL LiFe2-5120S selected and saved; SP PRO firmware 16.11 or later, comms card 5.31 or later; restart the battery DC supply |
| Selectronic SP PRO | Intermittent communication; multi-phase not reading | Comms card CAN termination DIP switch ON; CAN cable to the L1 SP PRO only |
| Solis | CAN Fail | Pins 4 and 5 at both ends; cable in COMM; Battery Model Lithium Battery LV, not the RS485 variant |
| Solis | BatName-FAIL / NO-Battery | Battery Model selection / DC breakers on and the battery on |
Full settings: LiFe² 5120S Managed Battery Integration Guide.
Kakadu 120 needs an AERL Nexus Gateway to manage the battery communications. Each cabinet holds two independent strings, each with its own BMS and HMI, so the system keeps operating if one string faults.
| Indicator | Normal | Otherwise |
|---|---|---|
| Run | Green: power on | Off: power off |
| Alarm | Off | Orange: a serious fault, such as over-voltage or over-current |
| Module status 1–4 | Off: module working | Number lit orange: that module has failed. Indicators 5–9 are not used |
| SOC | 1–5 bars, 20% each | Last bar flashes 1 Hz discharging, 0.5 Hz charging |
| Master Unit | Lit on the master string only | Lit on every string by default: press it on each string that is not the master |
| Last Unit | Lit on the last string only | Lit on every string by default: press it on each of the other strings |
| Black Start | Off | Green: black start on (off-grid start) |
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Alarm orange | A serious fault, such as over-voltage or over-current | The working logs, cell voltages and module temperatures through the Nexus in AERL Cloud | Note the HMI state and contact AERL support |
| A module number lit orange | That module has failed | — | Contact AERL support with the cabinet and string |
| Run off | String not started, or shut down | The MCB on each BMS is on (shutting down trips it automatically) | Turn on each BMS's MCB, then press its ON/OFF button |
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Inverter does not see the battery, or reports the wrong capacity | Master Unit, Last Unit or the comms chain | Master Unit lit on the master string only; Last Unit lit on the final string only; OUT of each BMS to IN of the next; a terminating resistor on COM2 of the last module of every string; INV of the master BMS on the CAN bus | Correct and confirm every string's Run is lit and the inverter reports the combined capacity |
| Selectronic SP PRO shows no Kakadu data | Cable pins or termination | The SP PRO to BMS cable (CAN on pins 4 and 5 at the BMS end; a straight-through patch lead will not work; cables made to the commissioning guide's Rev 1.1.5 or earlier used the wrong pins); the SP PRO CAN termination DIP switch ON; every SRX's CANBUS 120 Ω switch OFF; no plug at a mid-bus Nexus | Battery type BMS – SelectCell River Gum in SP LINK; Data View → Battery Management shows the BMS data |
| Off-grid system will not start | The inverter needs the battery to start | — | Power up the system, then hold Black Start for three seconds |
Full procedures: Kakadu 120 Installation and Operating Manual (chapters 5–8) and the Kakadu Commissioning Guide, SP PRO SPLC1202 & CoolMax SRX.
EG-600 (two circuits):
| Condition | All Clear | Circuit 1 fault | Circuit 2 fault | Buzzer |
|---|---|---|---|---|
| All Clear (insulation OK) | On | Off | Off | Off |
| Circuit 1 earth fault (DC+ or DC−) | Off | On | Off | Pulsing |
| Circuit 2 earth fault (DC+ or DC−) | Off | Off | On | Pulsing |
All Clear is green and the Circuit Fault LEDs are red. In a fault the buzzer sounds for about 1.5 s, then is silent for 1.5 s, until the fault clears.
EG-600-SC (one circuit):
| All Clear (green) | Fault (red) | Meaning |
|---|---|---|
| Solid on | Off | Normal operation |
| Off | Flashing (2 Hz) | Warning: a possible fault has been measured and is being confirmed. Relay and buzzer not yet active |
| Off | Solid on | Confirmed earth fault: the buzzer sounds and the alarm relay opens |
Both return to All Clear, and close their relays, by themselves once the insulation resistance is back above the trip threshold.
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Fault LED on, buzzer sounding | An earth fault below the trip threshold | Find the fault (below) | Repair it; the unit returns to All Clear |
| No LED lit | No supply | Supply 12–60 Vdc at the input, from a current-limited power supply, not a battery directly. EG-600-SC: the BATT/PSU jumper fitted only for a 12–15 Vdc supply | Correct the supply. Never fit the BATT/PSU jumper above 15 Vdc |
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| External monitor alarms, EarthGuard shows All Clear | The relay is fail-safe: it opens on an earth fault, a loss of power or a broken cable alike | The relay wiring to the monitor; the EarthGuard's supply | Repair the wiring or supply |
| Fault on a circuit with one pole bonded to earth (EG-600) | Ground fault mode on Floating | The circuit's ground fault mode in AERL Link | Positive Earth or Negative Earth, only if that pole is deliberately and permanently bonded to earth |
| Trips at a level you did not expect | Trip threshold | On firmware 2.2.1 the trip threshold is fixed at 30 kΩ; the sensitivity setting applies on later firmware | Check that 30 kΩ meets your local standards; if it does not, contact AERL |
| AERL Link shows an internal self-test fault (EG-600) | Device fault | — | Contact AERL support |
An earth fault can damage power conversion equipment (PCE) and connected components. Ask the PCE manufacturer before you simulate an earth fault. AERL takes no responsibility for damage caused by simulating an earth fault.
With the system isolated and the EarthGuard powered down, fit a 10–12 kΩ resistor (20 kΩ maximum; not supplied) between the + or − terminal of the circuit under test and the Earth terminal. Reconnect the battery, restore power and confirm the fault is reported (EG-600-SC: wait 15 seconds): Fault LED, buzzer, relay open. Power down, remove the resistor and reconnect. If nothing trips, check the EarthGuard is powered (one LED lit) and that you can measure the resistor, then repeat. The full procedure is in Chapter 08 of each user manual.
The Input Alive LED lights when the input breakers are closed. The Output Alive LED lights when the CoolPro is delivering output. The LCD alternates between the input and output measurements every 5 seconds, each with its voltage, current and the board temperature.
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Input Alive on, Output Alive off | All setpoints at zero | The three front-panel dials | Set the voltage, reference cell and current dials as in the setpoint procedure (Chapter 07) |
| Input Alive on, Output Alive off | Low-battery cut-out | Battery voltage against the cut-out for the selected nominal voltage (12 V: 11 V / 13 V; 24 V: 22 V / 26 V; 36 V: 33 V / 39 V; 48 V: 44 V / 52 V, cut-out / cut-in) and the battery voltage selector | Recharge the battery; press Low Batt Reset to cut back in at any voltage above the cut-out |
| Input Alive on, Output Alive off | Current interrupt terminals linked | The current interrupt terminals (Link On/Off) and any interrupt sequencer | Linked, the output is off: remove the link |
| Input Alive off | No input | Input breakers closed; battery voltage and polarity at the terminals | Correct the supply. If the battery is correct at the terminals, contact AERL |
| Output current below the Current dial setting | Another control mode is limiting: the voltage limit (ground bed resistance rises in dry periods) or the reference cell | Which dial is limiting | Raise that mode's dial until the current control mode limits again |
| Output breaker trips in storms | Surge currents shunted by the surge protection | Whether an output breaker or fuse is fitted | An output breaker or fuse is not recommended: remove it |
| Symptom | Likely cause | Check | Fix |
|---|---|---|---|
| Lightning damage on a long pipeline or tall structure | No Surge Buster | Structure longer than 100 m or higher than 10 m | Fit an AERL Surge Buster: it is required there |
| Readings drift | Calibration | Status flags (below) | Recalibration is a workshop operation: contact AERL |
Shut the CoolPro down in this order: turn all three dials fully anti-clockwise, check the LCD shows zero output for 10 seconds (Output Alive turns off), then open the input breakers.
| Symptom | Check |
|---|---|
| No response | Station address 40 and 9600 baud, 8-N-1 (factory defaults); RJ45 pins 3 (A), 6 (B) and 8 (GND) only; 120 Ω termination at both ends of the bus. A changed address or baud rate takes effect after a reset |
| Register 40003 always reads 0 | Normal: it is a write-only command trigger |
| Setpoints do not change over Modbus | Normal: the meter board is a monitoring path only. Output current, voltage limit and reference-cell setpoint are set on the front panel |
Status flags (register 30008): bit 2 input or bit 3 output measurement fault, bit 4 calibration invalid, bit 5 calibration missing, bit 6 temperature sensor fault. Contact AERL if any of these is set; bits 0 (startup) and 1 (daily reset) are normal.
| LED | State | Meaning |
|---|---|---|
| Green (Active) | Slow heartbeat (brief flash every ~1.5 s) | Device is powered and operating normally |
| Green (Active) | Off | Device is not powered |
| Red (Fault) | Solid on | Fault condition detected (e.g. watchdog initialisation failure) |
| Red (Fault) | Brief 3× flash | Float event acknowledgement |
| Yellow (CAN activity) | Brief blink | A CAN message has been transmitted or received |
| Yellow (CAN activity) | Off | No CAN bus activity |
At power-on all three LEDs light briefly as a self-test.
| Symptom | Possible causes | Solution |
|---|---|---|
| Green LED not flashing | 5 V power toggle on the SRX not enabled; poor connection to the SRX; faulty CAT6 cable | Turn the SRX's 5 V power toggle ON; check cable connections; try a different CAT6 cable |
| Red Fault LED solid on | Internal device fault; voltage sense connection; voltage out of range | Power-cycle the device; check the voltage sense connections; verify the battery is within 18–200 Vdc; contact AERL support |
| Yellow LED not blinking | No CAN traffic; CAN bus configuration | Check cable connections; verify the 120 Ω termination switch positions; restart the SRX |
| Symptom | Possible causes | Solution |
|---|---|---|
| Temperature not showing in AERL Link | 120 Ω termination not enabled; communication issue; device fault | Set the 120 Ω termination switch to ON; check cable connections; verify the green LED is lit |
| SRX solid red, −350 · −1055 · −1161, or Battery Sense Lost | The SRX has lost the temperature reading | The CAT6 cable and the Battery Sense LEDs (above) |
| Incorrect voltage reading | Poor voltage sense connection; improperly sized fuse; damaged sense wire | Check the voltage sense connections and fusing; inspect the wiring |
| Float switch input not working | Improper connection; external voltage applied | Use a normally open, voltage-free switch; apply no voltage; check the switch's continuity |
| Float indication output not working | Over the 12 V / 2 A rating; blown fuse; connection | Keep the load within rating; check or replace the fuse; verify connections |
The M2HT 25–50 inverter, also used in the All-In-One, shows each fault by name on its display; the All-In-One battery shows codes. Status codes (S01, S02 …) show the inverter's state and are not faults. Full lists: M2HT 25–50 user manual Chapter 08, All-In-One user manual section 7.3.
| Indicator | Colour | State | Meaning |
|---|---|---|---|
| Power and alarm | Blue | Fast flashing / slow flashing / breathing | Self-test / waiting / operating normally |
| Power and alarm | Orange | Breathing | Low battery: close to the SOC protection limit |
| Power and alarm | Red | On | Alarm or fault: check the display |
| Grid | — | Off / slow flashing / on | Grid lost / grid detected, not on-grid / operating on-grid |
| Communication | Green | On / flashing | Normal / communicating with an EMS or the master inverter |
| Communication | Orange | On | No communication with the smart meter |
| Communication | Red | On | No communication with the BMS |
| Message | What to do |
|---|---|
| Mains Lost | No grid detected: check the grid voltage, AC wiring and AC breaker |
| Grid Voltage Fault | Check the grid code and AC wiring, and the AC cable size (voltage rise). Widen the limits only with the network service provider's permission |
| ISO Over Limitation | Low DC insulation resistance to earth: check PV modules, batteries, DC cables and connectors for damage or water. It must be at least 500 kΩ |
| GFCI Fault | Excessive earth leakage: check PV modules, batteries, DC cables and connectors for damage or water |
| PV Over Voltage | Reduce the modules per string so the open-circuit voltage is below the inverter's maximum |
| Over Temperature | Check the ventilation; shut the inverter down to cool, then restart |
| N-PE Check Fault | Back-up earth loose or poorly connected: check the earth wiring, or turn N-PE Check off if the bond is not needed |
| Backup Load Fault | Reduce the back-up load; check the battery's discharge capacity |
| Message | What to do |
|---|---|
| Meter Comm Fault | Check the meter communication cable and that the meter model is compatible |
| BMS Comm Fault | Check the battery ID setting, the BMS cable and the battery status |
| PV Power Low | Check the PV connection and generation, and the battery output |
| BAT Power Low, BAT Invalid | Check the battery cables, breaker, switch or fuse and any battery alarm; restart the battery |
An earth fault on the PV array keeps the power indicator red and shows ISO Over Limitation or GFCI Fault until it is cleared; the app and portal show an alarm (email alerts can be set). Install the inverter where the indicator will be noticed.
Cabinet indicators: the audible and visual alarm sounds and flashes when the smoke sensor is triggered; Power (white) is on while grid power is present; Running (green) while the high-voltage box operates; Fault (red) when the cabinet has a fault. Check the alarm details in the monitoring data.
Battery codes starting with E are protection faults (the battery stops to protect itself); I are alarms and W warnings (the system keeps running).
| Code | Name | What to do |
|---|---|---|
| E400 | BMS communication | Check the battery type selected in the inverter, the battery status, and the communication cable and its pinout |
| E401 | Low SOC | Check the battery's communication and power connections, the inverter's PV, grid and generator connections, and whether the load is too large |
| E403 | BMS sleeping | Check that the grid or PV can supply stable power for long enough, and the battery power connection |
| E416 | Insulation fault | Shut down the whole system; check equipment, cables and terminals for damage and short circuits; restart the battery |
| E417 / I400 / W400 | Cell undervoltage | Check the inverter allows forced charging and the external source is running; charge the battery immediately (E417: restart the battery first) |
| Code | Name | What to do |
|---|---|---|
| E421 / I404 / W404 | Charge undertemperature | Check the temperature reading is plausible and the sensors; warm the battery (E421: then restart the battery) |
| E431 | Battery voltage abnormal | Check the battery power cables for damage and any battery alarm or protection; clear the problem, then restart the battery |
| E432 | Battery parallel number abnormal | Check the target number of clusters, the communication between clusters and the inverter, and that every cluster is switched on, free of alarms and within 2.5 V of the others; then re-run the paralleling process |
| E425 / I408 / W408 | Charge overcurrent | Check whether the battery's current limit was reduced and the inverter is charging above it; correct the configuration, restart the battery |
For any fault that persists after these checks, contact AERL support.
Have ready:
Contact AERL support on 1800 950 865 or [email protected].
Email the AERL RMA form, with any photos or screenshots, to [email protected] with the serial number as the subject. AERL replies with a Return Materials Authorisation (RMA) number: do not send a product without one. Then send the product, with its RMA number, to AERL, 1/75 Bluestone Circuit, Seventeen Mile Rocks QLD 4073, Australia. For a battery, wait for AERL's shipping instructions before you send it: lithium batteries are dangerous goods. The full process is in the AERL Warranty Claims and Returns Guide.
Warranty terms are in each product's warranty statement, at aerl.com.au. Register a product's warranty at aerl.com.au/warranty-registration.
| Revision | Date | Change |
|---|---|---|
| 1.0.0 | 11 / 2026 | First issue. |
If you have any questions or need support, contact AERL.