AERL technical documentation

CoolMax Battery Sense — Datasheet Rev 1.0.0

2 pages

Download PDF Print
Download PDF· Rev 1.0.0 CoolMax Datasheet

Battery Sense

Remote Temperature and Voltage Sensor

AERL CoolMax Battery Sense
18–200VdcVoltage sense input
CANRJ45To the CoolMax SRX
12V / 2 AFloat output relay
0.1WIdle consumption
aerl.com.au CoolMax Accessory · Battery Monitoring Datasheet · Rev 1.0.0 · 2026

Specifications

Battery Sense · BAT-SENSE

The Battery Sense is an accessory for the AERL CoolMax SRX solar charge controller. Mounted beside the battery bank, it measures the battery’s temperature and its voltage at the terminals and sends them to the SRX over CAN bus, so the controller compensates its charging for temperature (factory default 50 mV/°C per bank, set in AERL Link) and monitors the battery more accurately. Use it on banks that do not report their own temperature, typically flooded or sealed lead-acid; a battery whose BMS reports its temperature over CAN, such as an AERL LiFe², needs no Battery Sense.

Battery Sense top view with the three LEDs Voltage input side, 18–200 V Termination switch side, 120 Ω on / off
Connector side: CAN, USB, RLY and IN
Top view, voltage input and termination switch sides, connector side (CAN · USB · RLY · IN). Not to scale.

General

Weight
0.25 kg
Enclosure type
Indoor Type 1 / IP20
Mounting
Double-sided adhesive tape
Voltage input connector
Screw terminals, 0.5–2.5 mm²
Terminal torque
0.5 N·m

Electrical

Voltage input range
18–200 Vdc
Power supply
5 V from the SRX CAN port
Self-consumption at idle
0.1 W
Float indication output
NO relay, 12 V / 2 A, fused
Float switch input
NO, voltage-free
Status indicators
Active, Fault, CAN activity

Communication

Interface
CAN bus (RJ45)
Maximum cable length
10 m, CAT6
Termination
120 Ω, switchable
Controller
CoolMax SRX

Environmental

Operating temperature
−20 to 50 °C
Storage temperature
−30 to 70 °C
Relative humidity
95%, non-condensing
Maximum altitude
2000 m

AERL reserves the right to change any product, product specifications and data without notice to improve reliability, function, or design or otherwise.

Manufactured by

Australian Energy Research Laboratories
1/75 Bluestone Circuit, Seventeen Mile Rocks QLD 4073

Origin and warranty

Australian made2-year warranty

Contact

[email protected]
1800 950 865
aerl.com.au