AERL technical documentation

CoolMax SRX HV 300 — Datasheet Rev 005

2 pages

Download PDF Print
Download PDF· Rev 005 CoolMax Datasheet · Legacy Product

SRX HV 300

SRX HV 300/30 · SRX HV 300/40 · 120 V

AERL CoolMax SRX HV 300 charge controller
300VdcMax PV input
30 / 40AMax charge current
120VNominal battery
98.7%Peak efficiency
aerl.com.au MPPT Charge Controller · 120 V Datasheet · Rev 005 · 2026

Specifications

SRX HV 300/30 · SRX HV 300/40

The CoolMax SRX HV 300 is an MPPT solar charge controller for 120 V DC-coupled battery systems. It is no longer manufactured; this datasheet is re-issued for installed systems. For a new system, see the CoolMax SRX 600/30-120. Where two values are given, they are for the SRX HV 300/30 and SRX HV 300/40, in that order.

General

Weight
6.8 kg
Dimensions (W × H × D)
226 × 480 × 111 mm
Enclosure
Indoor Type 1 / IP20
Mounting
Wall, 8 × M5
I/O power connectors
Screw 8–42 mm²
Communications
RS485 (Modbus RTU) / CAN
Communications ports
RJ45 / USB Mini-B
Max conversion efficiency
98.7%
Self-consumption @ idle
100 mA at 20 V
Warranty
3 yr · 5 yr registered

Battery (output)

Nominal battery voltage
120 V
Battery voltage range
90–170 Vdc
Max charge current
30 A / 40 A
Nominal PV power @ 144 V absorb
4320 W / 5760 W
Charging method
3-stage (absorb, float, rebulk)
Temp. compensation
Yes (SRX-RTS sensor)

PV input

Max PV open-circuit voltage
300 V at lowest temperature
Max PV short-circuit current
25 A / 35 A
Min PV MPP voltage
1.3 × nominal battery voltage
PV array oversizing
Up to 140%
Startup voltage
40 Vdc
Overload behaviour
Operating point shift (power limitation)

Environment

Operating temperature
−20 to 60 °C
Storage temperature
−30 to 70 °C
Cabinet air exchange (40 °C intake)
18 / 20 m³/hour
Heatsink rise at full power
30 / 35 °C
Sealed inductors, conformal coating
Yes

Options

Ground fault detection (floating)
EarthGuard EG-600
Remote temperature sensor
SRX-RTS (3–10 m)

High input voltage for easier installation

PV array oversizing up to 140%

Reverse polarity & current protection

Built-in overload & thermal protection

Master/slave operation

Touch-screen configuration

Multi-stage battery charging

Australian engineered

Engineered and supplied by

Australian Energy Research Laboratories
1/75 Bluestone Circuit, Seventeen Mile Rocks QLD 4073

Conforms to

IEC 62109-1 EN 61000-6-3:2012 EN 61000-6-4:2012

Contact

1800 950 865
[email protected]
aerl.com.au