Energy Management System

Nexus EMS

The brain of your hybrid power system. Nexus EMS runs on the Nexus Gateway or Nexus HMI, sits above the site's device controllers and makes the energy decisions for all of them: solar, battery, inverters, generators and loads. On site, offline if need be, with no custom PLC programming.

تنزيل الموارد

الميزات الرئيسية

One Controller for the Whole Site

Solar charging, generator start and stop, battery charge and discharge, grid limits and load shedding, decided in one place instead of device by device.

Every Brand, One System

Inverters, batteries and generator controllers from different brands are read into one view of the site and served to SCADA on one Modbus TCP address.

Battery and Equipment Protection First

Protections take priority over operators and schedules. Every function can run dry first, logging what it would do, before it is allowed to act.

المواصفات الفنية

الميزات الرئيسية

  • Control: Every Source, Battery and Load
  • Integration: Every Brand, One System
  • Protection: Battery and Equipment First
  • Oversight: Every Decision on Record
  • Dry-Run Mode on Every Function
  • Runs on Nexus Gateway and Nexus HMI
  • Annual Licence per Gateway
ProductEnergy management system (EMS) software for hybrid and off-grid sites
Runs OnNexus Lite (NEXUS-LITE), Nexus 4G (NEXUS-4G) or Nexus HMI (NEXUS-HMI-10)
LicenceAnnual, per gateway. Activated in AERL Cloud
Included with Every GatewayMonitoring, AERL Cloud, and solar charge coordination and battery protections for AERL equipment
OperationOn site. Keeps running without an internet connection
Decision RateAbout once a second. Fast protection, synchronising and breaker control stay with each device
CommissioningEvery function runs in dry-run mode before it is armed
StatusPreliminary. Confirm availability of functions and equipment with AERL

Preliminary information. Functions and supported equipment are subject to change; confirm availability with AERL. Nexus EMS protects equipment and is not a functional safety system.

الموارد والوثائق

اطّلع على المواصفات الفنية وأدلة التركيب ووثائق الاعتماد

عرض 2 موارد

ورقة البيانات

Nexus EMS – Preliminary Datasheet

What Nexus EMS does, the equipment it works with and how it is licensed.

الدليل

Nexus EMS – System Integration Guide (Preliminary)

Designing a site around Nexus EMS: where it sits, the design rules, what a device needs to offer, SCADA and commissioning.

Planning a Hybrid or Off-Grid Site?

Send us your single-line diagram and the brands of your inverters and generator controllers. We will confirm what Nexus EMS can run on your site.

Trusted by

  • Santos
  • APA
  • Epic Energy
  • Rio Tinto
  • Western Power
  • Horizon Power